Sign In | Join Free | My lightneasy.org |
|
Brand Name : MEAN WELL
Model Number : WDR-60-5
Certification : CE
Place of Origin : CN
MOQ : 1 piece
Price : 1 USD
Payment Terms : L/C,T/T
Supply Ability : 3000 pieces per month
Delivery Time : 8-10 weeks
Packaging Details : cartons
Brand : MEAN WELL
Product Namee : WDR series
Output currency : 10A-1.25A
Rated power : 60W
Input frequency : 47 ~ 63Hz
DC voltgae : 5V /12V/24V/48V
Efficiency : 83.5%-90%
Protection : over voltgae / over load
Dimension : 32*125.2*102mm (W*H*D)
Weight : 0.45 kg
Mean Well 60W Ultra Wide Input Industrial DIN Rail Power Supply WDR-60 series WDR-60-5
1∅ and 2∅ , 180~550VAC wide input
High efficiency up to 93%
Built-in active PFC function (240W & 480W)
Assemble on industrial rail TS-35 / 7.5 or 15
Built-in DC OK relay contact
Technical
MODEL | WDR-60-5 | WDR-60-12 | WDR-60-24 | WDR-60-48 | |||
OUTPUT | DC VOLTAGE | 5V | 12V | 24V | 48V | ||
RATED CURRENT | 10A | 5A | 2.5A | 1.25A | |||
CURRENT RANGE | 0 ~ 10A | 0 ~ 5A | 0 ~ 2.5A | 0 ~ 1.25A | |||
RATED POWER | 50W | 60W | 60W | 60W | |||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |||
VOLTAGE ADJ. RANGE | 5 ~ 6V | 12 ~ 15V | 24 ~ 29V | 48 ~ 57V | |||
VOLTAGE TOLERANCE Note.3 | ±2% | ±1.5% | ±1.0% | ±1.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±1.5% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP, RISE, HOLD UP TIME | 1000ms, 70ms, 20ms/400Vac 2000ms, 70ms, 10ms/230Vac at full load | ||||||
INPUT | VOLTAGE RANGE Note.4 | 180 ~ 550Vac or 254 ~ 780Vdc | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 83.5% / 400Vac | 86.5% / 400Vac | 89% / 400Vac | 90.5% / 400Vac | |||
AC CURRENT | 0.4A/400Vac 0.7A/230Vac | ||||||
INRUSH CURRENT (max.) | COLD START 50A /400Vac 30A/230Vac | ||||||
LEAKAGE CURRENT | <2mA / 530Vac | ||||||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power | |||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 6.2 ~ 7.2V | 16 ~ 18V | 31 ~ 37V | 58 ~ 60.5V | |||
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Protection type : Shut down o/p voltage, re-power on to recover | ||||||
FUNCTION | DC OK SIGNAL | Relay contact rating(max.) : 30V / 1A resistive | |||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +85℃ (Refer to "Derating Curve") | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP. | -40 ~ +85℃ | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 60℃) | ||||||
VIBRATION | Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6 | ||||||
OPERATING ALTITUDE Note.5 | 2000 meters | ||||||
OVER VOLTAGE CATEGORY | Ⅲ; According to EN61558, EN50178, EN60664-1, EN62477-1, EN60204-1; altitude up to 2000 meters | ||||||
SAFETY & EMC (Note 7) | SAFETY STANDARDS | UL61010, BS EN/EN61558-2-16, AS/NZS 62368.1, EAC TP TC 004 approved; design refer to GL and BS EN/EN60204-1(By request) | |||||
WITHSTAND VOLTAGE | I/P-O/P:4.7KVAC I/P-FG:2.5KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Parameter | Standard | Test Level / Note | ||||
Conducted | BS EN/EN55032(CISPR32) | Class B | |||||
Radiated | BS EN/EN55032(CISPR32) | Class B | |||||
Harmonic Current | BS EN/EN61000-3-2 | Class A | |||||
Voltage Flicker | BS EN/EN61000-3-3 | ------- | |||||
EMC IMMUNITY | BS EN/EN55024, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3 | ||||||
Parameter | Standard | Test Level /Note | |||||
ESD | BS EN/EN61000-4-2 | Level 3, 8KV air; Level 2, 4KV contact, criteria A | |||||
Radiated Susceptibility | BS EN/EN61000-4-3 | Level 3, 10V/m, criteria A | |||||
EFT Bursts | BS EN/EN61000-4-4 | Level 3, 2KV/5KHz, criteria A | |||||
Surge | BS EN/EN61000-4-5 | Level 4, 2KV/Line-Line, 4KV/Line-Earth, criteria A | |||||
Conducted | BS EN/EN61000-4-6 | Level 3, 10V, criteria A | |||||
Magnetic Field | BS EN/EN61000-4-8 | Level 4, 30A/m, criteria A | |||||
Voltage Dips and interruptions | BS EN/EN61000-4-11 | >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods | |||||
OTHERS | MTBF | 1900.1K hrs min. Telcordia SR-332 (Bellcore) ; 313.7K hrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 32*125.2*102mm (W*H*D) | ||||||
PACKING | 0.45Kg; 28pcs/13.6Kg/1.24CUFT |
Solutions
We redefine telecom service delivery with AI-augmented site surveys, dynamic planning algorithms, AR-guided technical support, and blockchain-secured maintenance logs. Our global innovation labs and partner ecosystem drive industry-leading solutions.
FAQ :
1.Q: Can I get samples and see how much they cost?
2.Q: What happens if there's a quality problem?
3.Q: How good are the products?
4.Q: How long is the guarantee?
5.Q: What do I do if I get a bad product?
![]() |
60W Mean Well WDR-60-5 Rail Power Supply High Efficiency 93% Images |